The Cisco 300-615 exam is the perfect option for those individuals who want to validate their skills in troubleshooting the data center along with its network, storage, automation, operations, and more. This is one of the concentration tests designed for earning the CCNP Data Center certification, which must be taken after the core exam, known as 350-601 DCCOR. For those students who pass only the 300-615 test, the vendor will grant the Cisco Certified Specialist – Data Center Operations certificate.
NEW QUESTION 53
Refer to the exhibit.
The HSRP instance on both switches is showing as active. Which action resolves the issue?
- A. Configure the IP address of N9K-B on the same subnet as N9K-A.
- B. Configure preempt on only one of the switches.
- C. Allow VLAN 100 between the switches.
- D. Configure the HSRP timers to be the same.
Answer: C
NEW QUESTION 54
Refer to the exhibit.
An engineer deploys SAN environment with two interconnected Cisco MDS 9000 Series switches. When the engineer attempts a zone merge, it fails with the error that is presented in the exhibit. Which action resolves the issue?
- A. Set the distribute policy of the zone to full.
- B. Import or export a zone set between the switches to synchronize the switches.
- C. Change the name of one of the zones to match the other zone set.
- D. Ensure that the zone members have different names.
Answer: B
Explanation:
https://www.cisco.com/en/US/docs/storage/san_switches/mds9000/sw/rel_3_x/troubleshooting/guide/ts_guide.pdf
NEW QUESTION 55
An engineer must upgrade all components in a Cisco UCS domain to the same package version, but the upgrade process fails to complete. Which set of Auto Install actions resolves the problem?
- A. Install infrastructure Firmware, then Install Hypervisor Firmware.
- B. Install Infrastructure Firmware, then Install Server Firmware.
- C. Install Server Firmware, then Install Infrastructure Firmware
- D. Install Hypervisor Firmware, then Install Infrastructure Firmware
Answer: B
Explanation:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/firmware-mgmt/gui/2-5/b_GUI_Firmware_Management_25/b_GUI_Firmware_Management_25_chapter_0111.pdf
NEW QUESTION 56
Refer to the exhibit.
vPC between switch1 and switch2 is not working. Which two actions are needed to fix the problem? (Choose two.)
- A. Configure vPC peer link and vPC peer keepalive correctly.
- B. Activate VLANs on the vPC.
- C. Configure one of the switches as primary for the vPC.
- D. Match vPC domain ID between the two devices.
- E. Configure IP address on the interface.
Answer: B,D
NEW QUESTION 57
An engineer is troubleshooting a fabric discovery failure. Which two requirements must an engineer verify about switch connectivity to solve the problem? (Choose two.)
- A. A Cisco APIC must be attached to a spine node only.
- B. A Cisco APIC must be dual-attached to two separate spine nodes.
- C. Leaf nodes must connect to spine nodes only.
- D. A Cisco APIC must be attached to leaf nodes.
- E. Spine nodes must connect to other spine nodes.
Answer: C,D
NEW QUESTION 58
Refer to the exhibit.
An engineer is performing a health check on ACI. Which statement about interface Ethernet 1/11 is true?
- A. The interface is working correctly and fully operational, but it is not in use.
- B. The interface policy is misconfigured.
- C. "out-of-service" is the default interface status in ACI.
- D. "out-of-service" indicates that no service graph is in use for this interface.
Answer: B
NEW QUESTION 59
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a "No Signal" message from the vKVM and physical connection. Which set of steps resolves the issue?
- A. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - B. 1- Disconnect the power cord
2- Confirm that all cards are properly seated
3- Connect the power cord - C. 1- Disconnect the power cord
2- Confirm that all cards are property seated
3- Connect the power cord and power on the server - D. 1- Power off the server and disconnect the power cord
2- Confirm that all cards are available
3- Connect the power cord and power on the server
Answer: A
Explanation:
Explanation
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/ts/guide/b_C-Series_Troubleshooting_Guide.pd
NEW QUESTION 60
An engineer is troubleshooting a fabric discovery failure. Which two requirements must an engineer verify about switch connectivity to solve the problem? (Choose two.)
- A. A Cisco APIC must be attached to a spine node only.
- B. A Cisco APIC must be dual-attached to two separate spine nodes.
- C. Leaf nodes must connect to spine nodes only.
- D. A Cisco APIC must be attached to leaf nodes.
- E. Spine nodes must connect to other spine nodes.
Answer: C,D
Explanation:
Section: Network
NEW QUESTION 61
A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.
Answer:
Explanation:

NEW QUESTION 62
Refer to the exhibit.
A network engineer traces the packet flow from the Veth991 of a blade server toward the core switch. The switch reports performance issues What is the role of the interface Eth1/7?
- A. fabric interconnect uplink interface
- B. IOM host interface
- C. IOM network interface
- D. server interface
Answer: A
Explanation:
Explanation
E1/7 is border interface, which is used as uplink. All other veth interfaces are SIF, which stands for Server Interface.
NEW QUESTION 63
Drag and drop the commands from the left onto the correct categories on the right.
Answer:
Explanation:
NEW QUESTION 64
Refer to the exhibit.
The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?
- A. Reset the port for FC ID 0x970102 and FC ID 0x970200 to log in to the fabric.
- B. Reactivate the zoneset.
- C. Reset the port for FC ID 0x970209 and FC ID 0x9700c2 to log in to the fabric.
- D. Reconfigure the initiator and the target to be in the same zones.
Answer: D
NEW QUESTION 65
A server administrator attempts to change the Cisco IMC KVM certificate to one that is signed by a private CA, but the certificate is not accepted. What causes this process to fail?
- A. using RSA encryption in the generation of the certificate
- B. using AES encryption in the generation of the certificate
- C. using a certificate with a password-protected private key
- D. omitting the public IP address of the Cisco IMC in the SAN
Answer: C
Explanation:
Section: Management and Operations
NEW QUESTION 66
You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one-by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership.
What is the cause of the issue?
- A. You forgot to enter the TEP Pool value during the Initial Setup dialogue on APIC1.
- B. The leaf nodes were not erased properly, which caused a fabric parameters mismatch with the APIC1.
- C. The same Fabric Name value should be used before after wiping all devices.
- D. Rebooting the APICs and the leaf and spine switches after wiping them is not required.
Answer: A
NEW QUESTION 67
Refer to the exhibit.
After the configuration is performed, guestshell continues to use 2%CPU. Which action resolves the issue?
- A. Reboot the switch
- B. Resync the database
- C. Recreate the guestshell
- D. Reboot the guestshell
Answer: D
NEW QUESTION 68
You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one-by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership. What is the cause of the issue?
- A. You forgot to enter the TEP Pool value during the Initial Setup dialogue on APIC1.
- B. The leaf nodes were not erased properly, which caused a fabric parameters mismatch with the APIC1.
- C. The same Fabric Name value should be used before after wiping all devices.
- D. Rebooting the APICs and the leaf and spine switches after wiping them is not required.
Answer: A
Explanation:
Section: Compute Platforms
NEW QUESTION 69
......